| Name |
Brief description of instruments |
|
| Capillary Electrophoresis |
|
CAPEL-series
 more info |
CAPEL-series Capillary Electrophoresis Systems.
Capel-103 and its upgraded versions Capel-104, Capel-105 and 105M are high-performance CE instruments equipped with light sources and photometric detectors.
Models 103 and 104 operate at a single 254 nm wavelength, while Capel-105 is equipped with a detector
and UV monochromator, covering the 190-380 nm spectral range. Capel-103 has a manualy controlled
sampler with 4 inlet and 2 outlet positions, and Capel-104 and 105 have autosamplers with 10
inlet and 10 outlet positions. The samples, rinsing and buffer solutions are injected automatically
by pressure or electrokinetically according to a preset program. All the instruments are equipped
with capillary cassettes, containing air (103)- or liquid-cooled capillaries of 30-100-cm in length
and 25-100 ³m i.d., reversible polarity 25 kV voltage supply units, and with customized report
outputs (hard copy and file). The dedicated software package supports data acquisition and
processing, data exchanges with worksheets, databases and word processors. The software package
utilizes a standard PC and powerful Chrom&Spec software package. The Capel-105M version is fully computer-operated, using dedicated Elforun software
|
|
| Luminescent
and Absorption Photometric Analysis |
|
FLUORAT®-02-Panorama Spectrofluorometer
 more info |
FLUORAT®-02-Panorama Spectrofluorometer incorporates two
monochromators in the luminescence excitation and detection paths,
which are arranged in a compact two-storied configuration, a xenon
flashlamp as a light source, and a PMT as a detector of luminescence
signals. The monochromators employ 900-l/mm concave diffraction
gratings with a 100-mm radius of curvature, covering the 210-730 nm (up to 840 nm opt.)
spectral range. The wavelengths are set either from a built-in
keypad or using a computer control program. The instrument is
intended for analysis of liquid and solid samples by luminescence
spectra, chromatographic analysis of several components during
a single eluation, and synchronous or two-dimensional spectra
scanning in both excitation and luminescence detection paths.
|
FLUORAT®-02 series
 more info |
FLUORAT®-02-series Analyzers embody the modular principle
to diversify the highly sensitive and selective luminescent analysis
technique employed. The base unit, FLUORAT®-02, is a filter fluorometer,
photometer, and chemoluminometer, all implemented in the
same optoelectronic scheme, whereas the FLUORAT®-02-2M
version is, in addition, a time-resolving fluorometer, which can
be used as a fluorometric detector in any HPLC system. The analyzers
are equipped with high-pressure xenon arc lamps, which emit high-intensity
light in the 200-650-nm spectral range, and are furnished with
appropriate sets of light filters and measuring cells. FLUORAT®-02-02/3M
analyzers operate in a user-friendly custom menu mode to analyze
standard-list contaminants, such as petroleum hydrocarbons, phenols,
surfactants, formaldehyde, nitrites, nitrates, sulfides, fluorodes,
and a number of elements, save calibration tables and background
value for 16 different components in the built-in memory, and
can print out analysis results. These analyzers can also operate
with a fiber optic light guide to measure luminescence or reflected
light from the surface of an outside sample, such as paper, cathodoluminophors,
etc. The small (300x300x90 mm) and light-weight (8 kg) analyzers
are energized from an ac mains or from a 12-V battery, which allows
their use in mobile laboratories.
|
CRYO-1
and -2
 more info |
CRYO-1 and -2 Cryogenic Systems are, respectively, intended
for cryospectroluminescent analyses of benz(a)pyrene in various
objects and of lead in samples of potable, natural and waste water,
and in food products (in addition, Bi, Te, and Se can also be
detected). The systems comprise a FLUORAT®-02-2M analyzer and a
cryogenic unit (plus an LM-3 monochromator in Cryo-1), which are
connected with one another via fiber optic bundles. The cryogenic
unit, where a substance under study is cooled to 77K, using liquid nitrogen
consists of a rack, Dewar vessel, and a device
for the uniform feed of samples being measured.
|
|
| High
Performance Liquid Chromatography (HPLC) |
|
HPLC
system
 more info |
HPLC system is made up of a FLUORAT®-02-2M analyzer, used
as a detector, and a Python pump. The FLUORAT®-02-2M analyzer enables
the detection of mycotoxins, hormones, nitroso amines, histamine
and other biogenic amines, benz(a)pyrene, vitamins, etc. To record
chromatograms, the analyzer is equipped with an RS-232 interface.
A built-in microprocessor provides signal processing, acustomized report,
and makes the output signals compatible with the dedicated chromatographic
data processing PC Multichrome software. The Python syringe-type
pump provides a precise and predictable pulsation-free eluent
flow and pressure. It is specifically designed to handle aqueous,
organic, corrosive, and viscous liquids. The pump has a multifunctional
control unit with a built-in keypad, which simplifies routine
operations. Two pumps operating together can build up an eluent
gradient.
|
FLUORAT®-02-Panorama
detector
 more info |
To carry out very complicated analyses, for example, to analyze
polyaromatic hydrocarbons, it is convenient to use a spectrofruorimetric
FLUORAT®-02-PANORAMA analyzer. This instrument
enables program-controlled adjustment of both monochromators as
a function of the eluation time. In this configuration, several compounds,
for example, 15 specified polyaromatic hydrocarbons, can be detected
with the highest sensitivity.
|
|
| Water Quality
Analysis |
|
AKMC-1
 more info |
AKMC-1 Water Hardness Monitor is designed
for stand-alone unattended continuous monitoring. The principle of operation is
based on potentiometric determination of the high or low range (0.1 to 250 ppm) content of calcium and magnesium ions in any natural
or industrial water samples. The device may be used for monitoring at water preparation facilities
and for quality control of feed water in power plants and in artesian-well water softening.
The design of the instrument provides uninterrupted measurements of ion concentrations
in real time with automatic correction for variations of temperature in the water flow.
It is equipped with RS-485 and RS-232 computer interfaces for customized report output and
remote computer-aided control. Concentration measurement results, up to 1000, are stored in a
built-in memory and are displayed on a built-in LCD or can be printed out.
|
CKAT-1
 more info |
CKAT-1 on-line Turbidimeter Monitor is intended for stand-alone unattended continuous
monitoring in ecological, technological and sanitary purposes.
Principle of operation of this device is based on the effect of light scattering by suspended particles
and emulsions.
The instruments comprise a light source, a water flow-cell and a matrix of photodetectors and
allow to detect a turbidity in any natural and industrial water flows. The instruments are equipped
with RS-485 computer interfaces for customized report output and remote computer-aided control.
Concentration measurement results, up to 1000, are stored in a built-in memory and are displayed on a
built-in LCD or printed out. If the analysis result exceeds a permissible level, the alarm mode is
activated, and a final-control mechanism can be automatically switched off by a command from the flow
analyzer.
|
|
| Atomic Absorption Spectrometry |
|
RA-915+ Mercury Analyzer
 more info |
RA-915+ Mercury Analyzer
is a portable multifunctional atomic absorption spectrometer with Zeeman background correction,
which eliminates the effect of interfering impurities. It is the only high sensitivity and
selectivity instrument that does not require gold amalgam pre-concentration and subsequent
regeneration steps. This enables the user to conduct real time monitoring. Being combined
with an RP-91 Cold Vapor accessory for water and RP-91C pyrolysis attachment for solid sample
testing, the instrument is designed to determine mercury content in ambient air, water, soil,
natural and stack gases, dental and medical testing and diagnostics, analysis of food and marine
life, etc., the detection limits being as low as 2 ng/m3 in air and 0.5 ng/l in water.
|
MGA-915
 more info |
MGA-915 Atomic Absorption Spectrophotometer with electrothermal sample atomization
and enhanced Zeeman background correction features a compact benchtop design, incorporating a
fast 62.5-mm focal length monochromator with a 1200-l/mm grating covering the 195-600 nm spectral
range, automatically controlled Massman graphite furnace, and automatically interchangeable 6
hollow-cathode lamps or EDLs on a rotated turret. It enables an analysis of more than 60
elements, primarily heavy and toxic metals, to be carried out with very low detection limits
in such complex organic samples as milk, juices, wines, or blood without preliminary sample
digestion in a totally automated computer-aided operation mode, including automated adjustment
for the given element. The spectrophotometer is equipped with a 100-position autosampler.
|
|
| Microwave Sample Digestion |
|
MINOTAVR®-2
 more info |
MINOTAVR®-2 microwave digestion system.
Fast and complete sample digestion for determination of elements concentration.
No losses of the sample and its volatile components, because all the stages of the digestion process are carried out in the same closed vessel.
The consumption of oxidizing reagents is reduced 2-3-fold. The allowable weighed sample is increased to a dry weight of 2 g.
The digestion is carried out automatically according to a program assigned by the operator from a built-in keypad or computer
Safety of attending personnel. Methodological support
|
|
|